Magnetic pulse induction can be used to determine the thickness of concrete pavement in a nondestructive manner. This induction provides the same level of accuracy and can save time and money for state agencies when compared with coring the pavement for thickness determination. The MIT-SCAN-T2 is a commercially available device that uses magnetic pulse induction to measure pavement thickness. The technology and operation of this device are described. Field experience from various states is provided. The accuracy and the repeatability, when compared with measuring core lengths, are good on the basis of data collected to date. The advantages of this nondestructive testing are presented. A specification developed by the Iowa Department of Transportation is included. The paper also includes a discussion of other issues that may be raised when this technique is used or there is ongoing work related to implementation.
Nondestructive Tests of Thickness Measurements for Concrete Pavements
Tests Really Work
Transportation Research Record
Transportation Research Record: Journal of the Transportation Research Board ; 2268 , 1 ; 61-67
2012-01-01
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Transportation Research Record | 2003
|Thickness Tolerance for Portland Cement Concrete Pavements
Transportation Research Record | 2004
|PART 2 - RIGID PAVEMENTS - Thickness Tolerance for Portland Cement Concrete Pavements