The design of a failed, large 20 m3 polypropylene storage tank is compared with the recommendations of the German Code of Practice, DVS 2205, to which it allegedly conformed. It is shown that the tank was seriously underdesigned, and that the situation was exacerbated by the introduction of residual tensile in its walls during its manufacture.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Catastrophic failure of a polypropylene tank part II: comparison of the DVS 2205 code of practice and the design of the failed tank


    Weitere Titelangaben:

    Katastrophaler Bruch eines Polypropylentanks Teil II: Vergleich der Designvorschrift DVS 2205 mit der Konstruktion des gebrochenen Tanks


    Beteiligte:
    Weidmann, G.W. (Autor:in) / Lewis, P.R. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1999


    Format / Umfang :

    18 Seiten, 13 Bilder, 5 Quellen




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch





    Why the gas tank failed

    Rae, George | Engineering Index Backfile | 1899


    Polypropylene vacuum tank for electric automobile

    WANG BINGCHEN / SONG WEI / LI WENHUI et al. | Europäisches Patentamt | 2024

    Freier Zugriff

    X33 Hydrogen Tank Failure

    James Reeder | NTRS