This paper presents the results of performance tests of several dual-slot heat pipe test articles. The dual-slot configuration has a very high thermal transport capability and has been identified as a very promising candidate for the radiator system for the National Aeronautics and Space Administration (NASA) Space Station solar dynamic power modules. Two six-foot long aluminum heat pipes were built and tested with ammonia and acetone. A 20-ft long heat pipe was also built and tested with ammonia. The test results have been compared with performance predictions. A thermal transport capacity of 2000 W at an adverse tilt of one inch and a 1000 W capacity at an adverse tilt of two inches were achieved on the 20-ft long heat pipe. These values are in close agreement with the predicted performance limits. This work was performed by Grumman as part of the work under Contract NAS3-24665 for NASA-Lewis Research Center.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    High thermal-transport capacity heat pipes for space radiators


    Weitere Titelangaben:

    Waermerohre mit hoher Waermeleitfaehigkeit fuer Raumstation-Waermetauscher


    Beteiligte:
    Carlson, A.W. (Autor:in) / Gustafson, E. (Autor:in) / Roukis, S.L. (Autor:in)

    Erschienen in:

    SAE-Papers ; Jul ; 1-12


    Erscheinungsdatum :

    1987


    Format / Umfang :

    12 Seiten, 19 Bilder, 1 Tabelle, 7 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    High Thermal-Transport Capacity Heat Pipes For Space Radiators

    Carlson, Albert W. / Gustafson, Eric / Roukis, Susan L. | SAE Technical Papers | 1987