Risks of stray current corrosion in pipelines with isolation joints have been investigated. The subsea pipelines in question have cathodic protection with sacrificial anodes and are separated electrically from the onshore part with monoblock isolation joints. The onshore part is an above ground installation without cathodic protection, which creates a voltage shift of 400 mV across the isolation joint. This was also confirmed by measurements. One of the pipelines transports unprocessed wet gas from a subsea field and the isolation joint is internally coated. Three other pipelines contain a non conductive fluid and no internal coating is applied. The risk of stray current corrosion, given the case described, has been investigated with experimental testing using a large scale experimental model of an isolation joint and a modeling software with polarization curves as input.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Isolation joint stray currents experimental testing and modelling


    Beteiligte:
    Hesjevik, S.M. (Autor:in) / Hydro, Statoil (Autor:in)


    Erscheinungsdatum :

    2009


    Format / Umfang :

    20 Seiten, 2 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Stray currents in electric tramways

    Engineering Index Backfile | 1897


    DETECTING STRAY CURRENTS IN ELECTRIC RAILWAY SYSTEMS

    VAN OVERBEEKE FRANK / GRAVENDEEL BASTIAAN / VAN BEKKUM DIRK | Europäisches Patentamt | 2017

    Freier Zugriff

    Calculation of stray currents in underground structures

    Markvardt, G.G. | Engineering Index Backfile | 1955


    Magnetism and Stray Currents in Rotating Machinery

    Nippes, P.I. | Online Contents | 1996