The objective of the study was to obtain time-dependent thoracic and abdominal deflections of an anthropomorphic test device, the WorldSID dummy, in oblique impact using sled tests, and compare with post mortem human subject (PMHS) data. To simulate the oblique loading vector, the load wall was configured such that the thorax and abdominal plates were offset by twenty or thirty degrees. Deflections were obtained from a chestband placed at the middle thoracic level and five internal deflection transducers. Data were compared from the chestband and the transducer located at the same level of the thorax. In addition, data were compared with deflections from similar PMHS tests obtained using chestbands placed at the level of the axilla, xyphoid process, and tenth rib, representing the upper thorax, middle thorax, and abdominal region of the biological specimen. Peak deflections ranged from 30 to 85 mm in the dummy tests. Peak deflections ranged from 60 to 115 mm in PMHS. Under both obliquities, dummy deflection-time histories at the location along the chestband in close proximity to the internal deflection transducer demonstrated similar profiles. However, the peak deflection magnitudes from the chestband were approximately 20 mm greater than those from the internal transducer. Acknowledging that the chestband measures external deflections in contrast to the transducer which records internal ribcage deformations, peak deflections match from the two sensors. Deflection time histories were also similar between the dummy and PMHS in terms of morphology, although thoracic deflection magnitudes from the dummy matched more closely with PMHS than abdominal deflection magnitudes. The dummy deformed in such a way that peak deflections occurred along the lateral vector. This was in contrast to PMHS tests wherein maximum deflections occurred along the antero-lateral direction, suggesting differing deformation responses in the two models. In addition, peak deflections occurred earlier in the dummy than in PMHS. These preliminary results are valuable in future crashworthiness studies.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Deflections from two types of human surrogates in oblique side impacts


    Weitere Titelangaben:

    Deflektionen im Bereich von Thorax und Abdomen beim Seitenaufprall


    Beteiligte:


    Erscheinungsdatum :

    2008


    Format / Umfang :

    13 Seiten, 23 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Deflections from Two Types of Human Surrogates in Oblique Side Impact

    Yoganandan, N. / Pintar, F.A. / Association for the Advancement of Automotive Medicine | British Library Conference Proceedings | 2008


    Oblique Lateral Impact Biofidelity Deflection Corridors from Post-Mortem Human Surrogates

    Yoganandan, N. / Humm, J.R. / Arun, M.W.J. et al. | British Library Conference Proceedings | 2013


    Oblique Lateral Impact Biofidelity Deflection Corridors from Post Mortem Human Surrogates

    Pintar, Frank A. / Humm, John R. / Arun, Mike W. J. et al. | SAE Technical Papers | 2013


    Thoraco-Abdominal Deflection Responses of Post Mortem Human Surrogates in Side Impacts

    Pintar, Frank A. / Humm, John R. / Brasel, Karen H. et al. | SAE Technical Papers | 2012


    Instrumentation of Human Surrogates for Side Impact

    Sances, Anthony / Pintar, Frank A. / Yoganandan, Narayan et al. | SAE Technical Papers | 1996