Throughout this work the thermal behavior of an AHG (adsorptive natural gas) storage under dynamic discharge conditions at room temperature of 27 deg C was studied. The work was conducted in a gravimetrically built experimental unit where the storage chamber was equipped with axial and radial distributed thermocouples and the storage was discharged at different discharge rates. The results demonstrated that maximum methane discharge rate of 5 L/min in activated carbon/methane system resulted in the severest temperature drop corresponding to further drop of about 40 % compared to that at 1 L/min. This extreme thermal condition claimed a reduction of 15.2 % in methane dynamic delivery capacity with respect to the isothermal delivery capacity. Ethane and propane have high enthalpies of desorption, and hence high portions of these gases may influence the performance of ANG storages through their thermal impact. A gas mixture with 14.98 % and 14.54 % volumes of ethane and propane resulted in higher temperature drop than methane claiming a reduction of 19.4 % in the dynamic delivery capacity comparing with methane delivery capacity.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature


    Weitere Titelangaben:

    Wärmeübergangsverhalten eines Adsorptionserdgastanks während der dynamischen Entladungsphase bei Raumtemperatur


    Beteiligte:
    Ridha, Firas N. (Autor:in) / Yunus, Rosli M. (Autor:in) / Rashid, M. (Autor:in) / Ismail, Ahmad F. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    2007


    Format / Umfang :

    8 Seiten, 7 Bilder, 3 Tabellen, 21 Quellen




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch




    Intake valve thermal behavior during steady-state and transient engine operations

    Cowart,J. / Cheng,W. / Massachusetts Inst.of Technology,Cambridge,US | Kraftfahrwesen | 1999


    Transient behavior of axially grooved heat pipe with thermal energy storage

    CHOW, LOUIS / CHANG, WON / MORGAN, MICHEAL | AIAA | 1990


    Intake Valve Thermal Behavior During Steady-State and Transient Engine Operation

    Cowart, Jim / Cheng, Wai | SAE Technical Papers | 1999


    CRYOCOOLER WITH TRANSIENT THERMAL STORAGE

    ALAHYARI ABBAS A / KSHIRSAGAR PARAG M | Europäisches Patentamt | 2024

    Freier Zugriff