A test article representing an upper stage avionics thermal control system was developed and tested under simulated space environments of full-sun and no-sun. The upper stage avionics packages are located in space-viewing windows. Heat is carried from package mounting plates to cylindrical secondary radiator skins by heat pipes. Test results were correlated and simulated with an analytical model for the test article. The selected window module approach was found to the versatile, to allow repeated package removal with no performance penalty, and to operate satisfactory with a simulated one-heat-pipe-out failure. (Se)


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Heat pipes for upper stage avionics thermal control


    Weitere Titelangaben:

    Waermeleitrohr fuer die Regelung des Waermehaushalts von Raumfahrzeugen


    Beteiligte:
    Pleasant, R.L. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1978


    Format / Umfang :

    4 Seiten, 10 Bilder


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch





    Loop heat pipe for avionics thermal control

    Baldassarre, G.J. / Gernert, N.J. / Gottschlich, J. | Tema Archiv | 1996


    Loop Heat Pipe for Avionics Thermal Control

    Baldassarre, Gregg J. / Gottschlich, Joe / Gernert, Nelson J. | SAE Technical Papers | 1996