The use of acid addition to control alkaline scale formation in M.S.F. desalination plants results in a recirculating brine pH of 7.2 - 7.5. The use of an effective high temperature scale control additive results in a recirculating brine pH of 8.5 9.5. In laboratory tests the corrosion rate of ferrous metals was reduced by about 70 % and of non-ferrous metals by about 80 % as the brine pH was increased from 7.5 to 9.0. High recirculating brine pH should lead to better plant reliability and availability due to these lower corrosion rates.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    The effect of scale control additives on the corrosion rates of plant constructional materials


    Beteiligte:
    Finan, M. (Autor:in) / Harris, A. (Autor:in)


    Erscheinungsdatum :

    1976


    Format / Umfang :

    8 Seiten, 1 Bild, 4 Tabellen, 8 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Marine engineering constructional materials

    Schulz, B. | Engineering Index Backfile | 1927


    Constructional engineering crane

    LI MINGLIANG | Europäisches Patentamt | 2021

    Freier Zugriff

    Elevator for constructional engineering

    ZHANG SHIMING / YU WENDI / YANG WENJIAO et al. | Europäisches Patentamt | 2023

    Freier Zugriff

    Elevator for constructional engineering

    LIU NA / CHEN AISONG | Europäisches Patentamt | 2022

    Freier Zugriff

    Constructional engineering material elevator

    DONG QUE | Europäisches Patentamt | 2021

    Freier Zugriff