Excellent resistance to seawater corrosion is expected of repeater housing materials used in the CS-36M Submarine Cable system. This paper is concerned with the results of experiments on more than thirty specimens of copper alloys, steel and titanium alloys. The test reveals Be-Cu alloy to be more corrosion resistive than other materials. Parallel tests were carried out to determine the effect of housing part shape and for comparing repeater housing manufacturing processes.
Corrosion resistance in Be-Cu alloy used in repeater housing
Korrosionsbestaendigkeit bei Be-Cu-Legierungen, die in Telephonverstaerkergehaeusen eingesetzt werden
Titel japanisch
Electrical Communication Laboratories, Technical Journal ; 25 , 6 ; 985-1004
1976
20 Seiten, 24 Quellen
Aufsatz (Zeitschrift)
Japanisch
Submarine optical repeater housing
Tema Archiv | 1986
|Springer Verlag | 2022
|Bidirectional Manchester repeater