Abstract In the implementation of a compressor for a linear Stirling cryocooler, one major cost factor is the volume of magnet material required in the motor. Since the magnet material used is oftentimes the high energy-density rare earth types for size and high ambient operating temperature considerations, any reduction in the total magnet volume will result in a cost savings. The use of a variable reluctance linear motor configuration can be implemented into a compressor for a specified peak force, with a reduced amount of magnet material required. However, a variable reluctance motor has a non-linear force profile which also must be taken into account for optimal performance. This is especially critical when implementing cryocoolers which use gas bearings for long-life operation. Design data, and resulting performance for a linear free-piston Stirling-Cycle Cryocooler implemented using a variable reluctance motor are presented and compared to a conventional linear motor implementation.
Use of Variable Reluctance Linear Motor for a Low Cost Stirling Cycle Cryocooler
Cryocoolers 10 ; 111-118
2002-01-01
8 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Use of Variable Reluctance Linear Motor for a Low Cost Stirling Cycle Cryocooler
British Library Conference Proceedings | 1999
|Computer Analysis of Stirling Cycle Cryocooler
SAE Technical Papers | 1995
|Performance and Reliability Improvements in a Low-Cost Stirling Cycle Cryocooler
Springer Verlag | 2002
|Performance and Reliability Improvements in a Low-Cost Stirling Cycle Cryocooler
British Library Conference Proceedings | 2001
|