Abstract A G-M type coaxial pulse tube cryocooler is first optimized from three aspects: the dimensional layout of the pulse tube and regenerator, the filling materials in the regenerator, and the structure of the cold end heat exchanger. Three different types of phase shifters: needle valves, capillaries and asymmetry-nozzles are then employed at the hot end of the pulse tube for the adjustment of the phase between the gas mass flow and the pressure oscillations. The influences of DC flow are investigated experimentally. It is found that a proper positive DC flow has positive effects on the cooling performance of the coaxial pulse tube cryocooler.
Experimental Investigation of a G-M Type Coaxial Pulse Tube Cryocooler
Cryocoolers 12 ; 317-323
2003-01-01
7 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Experimental Investigation of a G-M Type Coaxial Pulse Tube Cryocooler
British Library Conference Proceedings | 2003
|A Study of Performance Improvement of the Coaxial Inertance Tube Pulse Tube Cryocooler
Springer Verlag | 2005
|A Study of Performance Improvement of the Coaxial Inertance Tube Pulse Tube Cryocooler
British Library Conference Proceedings | 2005
|Helium-3 Pulse Tube Cryocooler
British Library Conference Proceedings | 2003
|AIRS Pulse Tube Cryocooler System
British Library Conference Proceedings | 1997
|