For the design of shear connection in high shear areas of steel-concrete composite bridges, large shear studs can be an excellent alternative. Large studs can provide the convenience of removing concrete slab and the proper distribution of shear pockets for precast decks. Through the push-out tests on large stud shear connectors up to 30 mm, which are beyond the limitation of current limit state design codes, static and fatigue behaviors were investigated and comparisons with design equations were performed. Ultimate strength of the shear connection showed that the design shear strength in Eurocode-4 gives conservative values for large studs. Fatigue endurance obtained from the tests was slightly lower than the current S-N curve in Eurocode-4.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Experiments on limit state design of large stud shear connectors


    Weitere Titelangaben:

    KSCE J Civ Eng


    Beteiligte:
    Shim, Chang Su (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    2004-05-01


    Format / Umfang :

    6 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch





    Comparison of Static and Fatigue Behaviors between Stud and Perfobond Shear Connectors

    Wang, Bing / Huang, Qiao / Liu, Xiaoling | Online Contents | 2019


    Comparison of Static and Fatigue Behaviors between Stud and Perfobond Shear Connectors

    Wang, Bing / Huang, Qiao / Liu, Xiaoling | Springer Verlag | 2018



    Theoretical Study on the Influence of Welding Collar on the Shear Behavior of Stud Shear Connectors

    Zhan, Yulin / Lu, Siji / Zheng, Yuanbiao et al. | Springer Verlag | 2021