The high throughput soft X-ray optical system was designed, constructed and tested for obtaining of magnified images of nonradiating objects at wavelength (lambda) equals 175...200 angstroms. The optical system consists of normal incidence multilayer mirrors including condenser and Schwarzschild objective with 10X magnification and it was applied together with laser produced plasma as an X-ray source. The magnified images with 0.7 micrometers resolution were produced in one shot exposure at 0.8...1 J of incident laser energy. These results show the potential for development of table-top soft X-ray microscopes with 1 nanosecond exposure and submicron spatial resolution.
Soft x-ray submicrometer imaging experiments with nanosecond exposure
Ultrashort Wavelength Lasers II ; 1993 ; San Diego,CA,United States
Proc. SPIE ; 2012
1994-02-01