The parameters of time, temperature, and turbulence affect the efficiency of incinerators in the control of organic solvent emissions from stationary equipment. Fuel costs are a problem, however, on which more data are needed. For example, for a large incinerator with no heat recovery features, the installed cost may be as low as $1.75/cfm for a 23,000 cfm unit with a fuel cost as low as $23/hr. A small unit without heat recovery but using no external combustion air might cost $11/cfm.The cost of equipment and operation is directly proportional to the exhaust volume to be handled.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    A Cost-Performance Summary of Air Pollution Control Equipment Used for Rule 66 Compliance


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Hayes, J. G. (Autor:in)

    Kongress:

    Aeronautic and Space Engineering and Manufacturing Meeting ; 1967



    Erscheinungsdatum :

    1967-02-01




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Cyclists' accidents and rule compliance

    van Schagen,I. / Brookhuis,K. / Wierda,M. et al. | Kraftfahrwesen | 1988


    Management Toolkits: Solutions for Rule Compliance

    Berman, J. / Ackroyd, P. / Mills, A. et al. | British Library Conference Proceedings | 2007



    Rule 66 - A Part of Total Air Pollution Control

    Dorn, Warren M. | SAE Technical Papers | 1967