The paper presents the benefits of a preinducer on the performance of a high-speed centrifugal pump. The study is carried out by introducing a preinducer upstream of the main inducer of a centrifugal pump. The test methodology consists of non-cavitation and cavitation tests at design and off-design conditions. The tests are carried out with and without the preinducer to obtain a comparison of the effect of the preinducer. The study provides the design parameters of the preinducer, the details of the test rig, the test article configuration, and details of the test conducted to find out the performance of the preinducer. It also gives the effect of the preinducer on the noncavitating behavior, cavitation inception, and net positive suction head corresponding to the 3% head drop for the centrifugal pump.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Effect of Preinducer in Reducing Net Positive Suction Head Requirement of a Pump



    Erschienen in:

    Erscheinungsdatum :

    2016




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch



    Klassifikation :

    BKL:    55.50 Luftfahrzeugtechnik / 55.50
    Lokalklassifikation TIB:    770/7040




    Effect of Preinducer in Reducing Net Positive Suction Head Requirement of a Pump

    Abraham, Aji M. / Panigrahi, Sridhar / Suresh, M. S. | AIAA | 2016




    Suction Jet Pump

    PAUER BERND / LÜCKE BASTIAN | Europäisches Patentamt | 2019

    Freier Zugriff