This article presents fault ride-through schemes for a three-phase quasi Z source single-stage photovoltaic (PV) inverter that is connected to the grid after the distribution network. The quasi Z source inverter employs a unique LC network to couple the inverter main circuit to the input of the PV panel. By controlling the shoot-through duty cycle, the quasi Z source inverter can theoretically produce any desired output AC voltage, even greater than the line voltage. Three different control strategies to improve the low-voltage ride-through capability are proposed when there is voltage sag from the grid side so that the grid fault ride-through requirements can be fulfilled. Scheme A involves control modification in the system; Schemes B and C involve hardware modification in the circuit topology by adding a chopper circuit across the DC link in Scheme B and across the quasi Z source inverter capacitor in Scheme C. A comparative study among the different control schemes is carried out to see the effectiveness of the control schemes under different types of symmetrical and unsymmetrical fault conditions. Observations based on comparing simulations and recommendations are reported.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Fault Ride-through of a Grid-connected Photovoltaic System with Quasi Z Source Inverter




    Erscheinungsdatum :

    2016




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch



    Klassifikation :

    BKL:    53.33 / 53.33 Elektrische Maschinen und Antriebe



    Research on Photovoltaic Grid Connected Inverter Without Isolation Transformer

    Yang, Tao / Wang, Wenxuan / Zhou, Jun et al. | Springer Verlag | 2022


    Maximum power point tracking and space vector modulation control of quasi-z-source inverter for grid-connected photovoltaic systems

    Jaoide, Essaid / El Aamri, Faicel / Outazkrit, Mbarek et al. | BASE | 2024

    Freier Zugriff

    Research on Photovoltaic Grid Connected Inverter Without Isolation Transformer

    Yang, Tao / Wang, Wenxuan / Zhou, Jun et al. | TIBKAT | 2022


    Multilevel inverter based Grid Connected Solar Photovoltaic System with Power Flow Control

    Mittal, Arvind / Janardhan, Kavali / Ojha, Amit | IEEE | 2021


    Three-phase grid connected inverter for photovoltaic systems, a review

    Mechouma, R. / Azoui, B. / Chaabane, M. | IEEE | 2012