This paper presents recession measurements of arc-jet test articles that simulate an ablator with gap filler and were exposed to various heating profiles. Results were used to derive empirically-based differential recession models used for the baseline sizing of the Orion block heatshield architecture. The profile test conditions represent different local flight environments associated with different regions of the heatshield. Recession measurements were collected during and after arc-jet tests, and the results were used to observe the heating profiles’ effect on differential recession. Arc-jet tests were conducted at the Aerodynamic Heating Facility at NASA Ames Research Center.
Assessment of Fencing on the Orion Heatshield
AIAA Thermophysics Conference ; 2016 ; Washington, D.C., United States
2016-06-13
Aufsatz (Konferenz)
Keine Angabe
Englisch
Assessment of Fencing on the Orion Heatshield
NTRS | 2016
|Assessment of Fencing on the Orion Heatshield
AIAA | 2016
|Analysis of Compression Pad Cavities for the Orion Heatshield
British Library Conference Proceedings | 2009
|