This paper presents experimental and computational comparisons of three active damping control laws applied to a complex laboratory structure. Two reduced structural models were used with one model being corrected on the basis of measured mode shapes and frequencies. Three control laws were investigated, a time-invariant linear quadratic regulator with state estimation and two direct rate feedback control laws. Experimental results for all designs were obtained with digital implementation. It was found that model correction improved the agreement between analytical and experimental results. The best agreement was obtained with the simplest direct rate feedback control.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Active vibration control with model correction on a flexible laboratory grid structure


    Beteiligte:


    Erscheinungsdatum :

    1991-10-01



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :



    Active vibration control of flexible structure using piezoelectric sensor/actuator

    Tao, Y. / Zhou, J. / He, Y. et al | British Library Online Contents | 1997


    System identification and active vibration control of a flexible structure

    de Abreu, Gustavo Luiz C. M. / da Conceicao, Sanderson M. / Lopes, Vicente et al. | BASE | 2012

    Freier Zugriff

    Semi-active vibration control of flexible structures

    Gaul,L. / Nitsche,R. / Sachau,D. et al. | Kraftfahrwesen | 1999


    Semi-active vibration control of flexible structures

    Gaul, L. / Nitsche, R. / Sachau, D. | Tema Archiv | 1998