A 20 kWh electric vehicle battery, Z20-low profile, was assembled and tested as part of a contract sponsored by Sandia National Laboratories (SNL). Cycling included capacity tests, power tests, and standing self-discharge tests. A 20 kWH load-leveling module was also designed, assembled, and tested at the recently completed load management test facility at JCI. Two 21 kWh battery systems were constructed and tested in a modified full size Dodge van. This was the first integrated demonstration of a zinc-bromine battery in a road worthy vehicle. The vehicle was equipped with full instrumentation to study the battery's characteristics under actual driving conditions. (ERA citation 12:036946)
Zinc-Bromine Battery Development
1987
6 pages
Report
Keine Angabe
Englisch
Zinc/Bromine Battery Development
AIAA | 1987
|Zinc/bromine battery development for electric vehicle application
Kraftfahrwesen | 1991
|Online Contents | 1994
|Experiences with 20 kWh zinc-bromine-battery
Kraftfahrwesen | 1993
|Zinc-bromine battery design for electric vehicles
Tema Archiv | 1983
|