An internal mode converter with an axially studied cavity (V-2005) has been installed and successfully tested for the 110 GHz, 1.5 MW gyrotron at MIT. A good Gaussian beam was observed with an output power of 1.5 MW, operating at beam voltage of 96.6 kV and current of 42 A. The Gaussian beam waist was determined, and was found to be in good agreement with the designed value. Single-stage depressed collector experiment has been also carried out. The efficiency was 50 % at the output power of 1.5 MW at the depressed voltage of 25 kV.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Single-Stage Depressed Collector Experimental Results from a 110 GHz 1.5 MW Gyrotron at MIT


    Beteiligte:
    Choi, E. M. (Autor:in) / Shapiro, M. A. (Autor:in) / Sirigiri, J. R. (Autor:in) / Temkin, R. J. (Autor:in)


    Erscheinungsdatum :

    2006-09-01


    Format / Umfang :

    983062 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    A High-Efficiency Second-Harmonic Gyrotron with a Depressed Collector

    Morozkin, M. V. / Glyavin, M. Y. / Denisov, G. G. et al. | British Library Online Contents | 2008


    Operation of a 1.5-MW, 110-GHz gyrotron depressed collector experiment

    Anderson, J.P. / Shapiro, M.A. / Temkin, R.J. et al. | IEEE | 2004


    Experimental Investigation of a 110 GHz/1 MW Gyrotron with the One-Step Depressed Collector

    Glyavin, M. Y. / Kuftin, A. N. / Venediktov, N. P. et al. | British Library Online Contents | 1997