The US Army Engineer Waterways Experiment Station conducted an evaluation of the discharge rating curves being used for determining flow rates through the Lockport control works and the power plant sluice gates. The revised curves are to be used by The Metropolitan Sanitary District of Chicago, Illinois, in future flow computations. The study resulted in the recomputation of the rating curves for the power plant sluice gates and for the control works. The control works analysis covered both submerged and unsubmerged flow conditions. Operational recommendations and proposed flow monitoring revisions were also addressed.
Lockport Power Plant Sluice Gate and Control Works Discharge Evaluation
Miscellaneous Paper ; HL-85-4
1985
19343851
Report
Elektronische Ressource
Englisch
Lift Gate for Lockport Lock, Illinois Waterway: Hydraulic Model Investigation
HENRY – Bundesanstalt für Wasserbau (BAW) | 1987
|Steam railroad conversion near Lockport
Engineering Index Backfile | 1898
Scouring Downstream of Sluice Gate
HENRY – Bundesanstalt für Wasserbau (BAW) | 2002
|