This report presents data obtained during prototype tests concerned with the vibration of a 106-3/4-in.-diam Howell-Bunger valve at Summersville Dam, Gauley River, W. Va . Prototype measurements include both dynamic and time-averaged values of pressures in the flow and strain at locations on the valve structure. Transverse, vertical, and peripheral accelerations were measured at the downstream end of the valve cone. The data were recorded simultaneously on analog magnetic tape and on oscillograph charts. Data reduction was by scaling the oscillograph traces and by using electronic analog equipment to perform linear spectral density, amplitude density, and cross-correlation analyses on the magnetic tape data. The results include information on (a) discharge characteristics of the Summersville outlet works, (b) evaluation of the nature of the pressure fluctuations in the flow, and (c) evaluation of the nature of the vibration (including approximate natural frequency values) of the valve at the strain gage and accelerometer locations. The primary conclusion regarding the vibration is that the significant strain fluctuations are caused by low-frequency pressure fluctuations buffeting the valve. These frequencies are well below the natural frequencies of the structure.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Howell-Bunger Valve Vibration, Summersville Dam Prototype Tests



    Erschienen in:

    Erscheinungsdatum :

    1971


    Format / Umfang :

    7789353


    Medientyp :

    Report


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :



    Howell automobile torpedo

    Engineering Index Backfile | 1890


    The howell disappearing carriage

    Engineering Index Backfile | 1900



    Fixed-Cone Valve Prototype Tests, New Melones Dam, California

    Fagerburg, Timothy L. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1983

    Freier Zugriff