Method consists of placing sample of fibers on microscope slide, superimposing circle of known diameter on fibers, counting number of ends inside circle and number of fibers crossing circle; from these counts average fiber length can be calculated on theoretically sound basis; trial was made by placing paper strips of known length on flat surface and comparing results of method with actual average length.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Determination of average fiber length


    Weitere Titelangaben:

    Tappi


    Beteiligte:
    Kane, M.W. (Autor:in)

    Erschienen in:

    Tappi ; 39 , n 7


    Erscheinungsdatum :

    1956


    Format / Umfang :

    3 pages


    Medientyp :

    Aufsatz (Zeitschrift)