PURPOSE: Respiratory motion compensation in PET/CT and PET/MRI is essential as motion is a source of image degradation (motion blur, attenuation artifacts). In previous work, we developed a direct method for joint image reconstruction/motion estimation (JRM) for attenuation-corrected (AC) respiratory-gated PET, which uses a single attenuation-map (μ-map). This approach was successfully implemented for respiratory-gated PET/CT, but since it relied on an accurate μ-map for motion estimation, the question of its applicability in PET/MRI is open. The purpose of this work is to investigate the feasibility of JRM in PET/MRI and to assess the robustness of the motion estimation when a degraded μ-map is used. METHODS: We performed a series of JRM reconstructions from simulated PET data using a range of simulated Dixon MRI sequence derived μ-maps with wrong attenuation values in the lungs, from -100% (no attenuation) to +100% (double attenuation), as well as truncated arms. We compared the estimated motions with the one obtained from JRM in ideal conditions (no noise, true μ-map as an input). We also applied JRM on 4 patient datasets of the chest, 3 of them containing hot lesions. Patient list-mode data were gated using a principal component analysis method. We compared SUVmax values of the JRM reconstructed activity images and non motion-corrected images. We also assessed the estimated motion fields by comparing the deformed JRM-reconstructed activity with individually non-AC reconstructed gates. RESULTS: Experiments on simulated data showed that JRM-motion estimation is robust to μ-map degradation in the sense that it produces motion fields similar to the ones obtained when using the true μ-map, regardless of the attenuation errors in the lungs (< 0.5% mean absolute difference with the reference motion field). When using a μ-map with truncated arms, JRM estimates a motion field that stretches the μ-map in order to match the projection data. Results on patient datasets showed that using JRM improves the SUVmax values ...


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation.


    Beteiligte:
    Bousse, A (Autor:in) / Manber, R (Autor:in) / Holman, BF (Autor:in) / Atkinson, D (Autor:in) / Arridge, S (Autor:in) / Ourselin, S (Autor:in) / Hutton, BF (Autor:in) / Thielemans, K (Autor:in)

    Erscheinungsdatum :

    2017-05-12


    Anmerkungen:

    Med Phys (2017) (In press).


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    531 / 629



    Respiratory Motion Correction in Dynamic PET with a Single Attenuation Map

    Emond, EC / Bousse, A / MacHado, M et al. | BASE | 2019

    Freier Zugriff

    Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI.

    Grimm, Robert / Fürst, Sebastian / Souvatzoglou, Michael et al. | BASE | 2017

    Freier Zugriff

    Autoadaptive motion modelling for MR-based respiratory motion estimation

    Baumgartner, CF / Kolbitsch, C / McClelland, JR et al. | BASE | 2017

    Freier Zugriff

    Autoadaptive motion modelling for MR-based respiratory motion estimation

    Baumgartner, Christian F. / Kolbitsch, Christoph / McClelland, Jamie R. et al. | BASE | 2017

    Freier Zugriff

    Joint PET-MR respiratory motion models for clinical PET motion correction

    Manber, R / Thielemans, K / Hutton, BF et al. | BASE | 2016

    Freier Zugriff