BACKGROUND AND PURPOSE: Conventional CT often cannot distinguish hemorrhage from iodine extravasation following reperfusion therapy for acute ischemic stroke. We investigated the potential of spectral detector CT in differentiating these lesions. MATERIALS AND METHODS: Centrifuged blood with increasing hematocrit (5%-85%) was used to model hemorrhage. Pure blood, blood-iodine mixtures (75/25, 50/50, and 25/75 ratios), and iodine solutions (0-14 mg I/mL) were scanned in a phantom with attenuation ranging from 12 to 75 HU on conventional imaging. Conventional and virtual noncontrast attenuation was compared and investigated for correlation with calculation of relative virtual noncontrast attenuation. Values for all investigated categories were compared using the Mann-Whitney U test. Sensitivity and specificity of virtual noncontrast, relative virtual noncontrast, conventional CT attenuation, and iodine quantification for hemorrhage detection were determined with receiver operating characteristic analysis. RESULTS: Conventional image attenuation was not significantly different among all samples containing blood (P > .05), while virtual noncontrast attenuation showed a significant decrease with a decreasing blood component (P < .01) in all blood-iodine mixtures. Relative virtual noncontrast values were significantly different among all investigated categories (P < .01), with correct hemorrhagic component size estimation for all categories within a 95% confidence interval. Areas under the curve for hemorrhage detection were 0.97, 0.87, 0.29, and 0.16 for virtual noncontrast, relative virtual noncontrast, conventional CT attenuation, and iodine quantification, respectively. A 10-HU virtual noncontrast, 20-HU virtual noncontrast, 40% relative virtual noncontrast, and combined 10-HU virtual noncontrast and 40% relative virtual noncontrast attenuation threshold had a sensitivity/specificity for detecting hemorrhage of 100%/23%, 89%/95%, 100%/82%, and 100%/100%, respectively. CONCLUSIONS: Spectral detector CT can accurately differentiate blood from iodinated contrast in a phantom setting.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Differentiation of Hemorrhage from Iodine Using Spectral Detector CT: A Phantom Study


    Beteiligte:
    Van Hedent, S. (Autor:in) / Hokamp, N. Groe (Autor:in) / Laukamp, K. R. (Autor:in) / Buls, N. (Autor:in) / Kessner, R. (Autor:in) / Rose, B. (Autor:in) / Ros, P. (Autor:in) / Jordan, D. (Autor:in)

    Erscheinungsdatum :

    2018-01-01


    Anmerkungen:

    Van Hedent, S., Hokamp, N. Groe, Laukamp, K. R., Buls, N., Kessner, R., Rose, B., Ros, P. and Jordan, D. (2018). Differentiation of Hemorrhage from Iodine Using Spectral Detector CT: A Phantom Study. Am. J. Neuroradiol., 39 (12). S. 2205 - 2211. DENVILLE: AMER SOC NEURORADIOLOGY. ISSN 1936-959X


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch


    Schlagwörter :

    Klassifikation :

    DDC:    629



    Phantom der Oper. Rolls Royce Phantom

    Wyler,M. / Rolls-Royce Motor,GB | Kraftfahrwesen | 2003



    Phantom Wild - Fahrbericht Rolls-Royce Phantom Coupe

    Bangemann,C. / Rolls-Royce Motor,GB | Kraftfahrwesen | 2008


    British phantom

    Wilson, M. | Engineering Index Backfile | 1966


    Phantom knight

    Engineering Index Backfile | 1929