This paper presents a novel method for the calibration of a parallel robot, which allows a more accurate configuration instead of a configuration based on nominal parameters. It is used, as the main sensor with one camera installed in the robot hand that determines the relative position of the robot with respect to a spherical object fixed in the working area of the robot. The positions of the end effector are related to the incremental positions of resolvers of the robot motors. A kinematic model of the robot is used to find a new group of parameters, which minimizes errors in the kinematic equations. Additionally, properties of the spherical object and intrinsic camera parameters are utilized to model the projection of the object in the image and thereby improve spatial measurements. Finally, several working tests, static and tracking tests are executed in order to verify how the robotic system behaviour improves by using calibrated parameters against nominal parameters. In order to emphasize that, this proposed new method uses neither external nor expensive sensor. That is why new robots are useful in teaching and research activities. ; Fil: Traslosheros, Alberto. Universidad Aeronáutica de Querétaro; México ; Fil: Sebastián, José María. Universidad Politecnica de Madrid; España ; Fil: Torrijós, Jesús. Universidad Politecnica de Madrid; España ; Fil: Carelli Albarracin, Ricardo Oscar. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Juan. Instituto de Automática; Argentina ; Fil: Castillo, Eduardo. Instituto Politécnico Nacional; México


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    An Inexpensive Method for Kinematic Calibration of a Parallel Robot by Using One Hand-Held Camera as Main Sensor



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    629




    An inexpensive method for kinematic calibration of a parallel robot by using one hand-held camera as main sensor

    Traslosheros, A. / Sebastián, José M. / Torrijos, J. et al. | BASE | 2013

    Freier Zugriff

    An Inexpensive Method for Kinematic Calibration of a Parallel Robot by Using One Hand-Held Camera as Main Sensor

    Traslosheros Michel, Alberto / Sebastian y Zuñiga, Jose Maria / Torrijos, Jesús et al. | BASE | 2013

    Freier Zugriff

    One Camera in Hand for Kinematic Calibration of a Parallel Robot

    Traslosheros Michel, Alberto / Sebastian y Zuñiga, Jose Maria / Castillo, Eduardo et al. | BASE | 2010

    Freier Zugriff

    A method for Kinematic Calibration of a Parallel Robot by using one camera in hand and a spherical object

    Traslosheros Michel, Alberto / Sebastian y Zuñiga, Jose Maria / Castillo, Eduardo et al. | BASE | 2011

    Freier Zugriff

    Kinematic calibration of a wire-actuated parallel robot

    Varziri, M.Saeed | Online Contents | 2007