Background. Treadmill training augmented with visual images projected on the belt's surface can help improve walking adaptability. Moreover, patient-Tailored automatization and standardization can increase the feasibility of walking-Adaptability therapy. We developed C-Gait, a treadmill protocol consisting of a baseline walking-Adaptability assessment involving 7 putatively distinct walking-Adaptability tasks and a decision algorithm, to automatically update training content and execution parameters to a patients' performance and perceived challenge. Objectives. The main objective was to examine the feasibility, acceptability, and clinical potential of C-Gait training. The secondary objective was to evaluate the validity of the baseline assessment. Design. This was a longitudinal proof-of-concept study with pretraining, posttraining, and retention tests encompassing baseline assessment and walking-related clinical measures. Methods. Twenty-four healthy adults, 12 healthy older persons, and 28 patients with gait and/or balance deficits performed the baseline assessment; the gait deficit group received 10 C-Gait training sessions over a 5-week period. Baseline assessment scores and walkingrelated clinical measures served as outcome measures. Results. C-Gait training exhibited significant progression in training content and execution, with considerable between-patient variation and minimal overruling by therapists. C-Gait training was well accepted and led to improvements in walking adaptability and general walking ability, which persisted after training cessation. Baseline assessment scores differed over groups and difficulty levels, had no-To-moderate correlations with walkingrelated clinical measures, and had limited correlations among walking-Adaptability tasks. Limitations. C-Gait was evaluated in a small yet diverse cohort. More encompassing studies are required to further establish its apparent merits. The validity of treadmill-based walking-Adaptability assessment against an overground standard remains to be established. Conclusions. C-Gait offers automatized, standardized, and patient-Tailored walkingadaptability training that is feasible and well accepted, with good potential for improving task-specific and generic measures of walking.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Automatized, standardized, and patient-Tailored progressive walking-Adaptability training: A proof-of-concept study


    Beteiligte:

    Erscheinungsdatum :

    2019-07-01


    Anmerkungen:

    Timmermans , C , Roerdink , M , Janssen , T W J , Beek , P J & Meskers , C G M 2019 , ' Automatized, standardized, and patient-Tailored progressive walking-Adaptability training: A proof-of-concept study ' , Physical Therapy , vol. 99 , no. 7 , pp. 882-891 . https://doi.org/10.1093/ptj/pzz013



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch


    Klassifikation :

    DDC:    629



    Automatized, standardized, and patient-tailored progressive walking-adaptability training:A proof-of-concept study

    Timmermans, Celine / Roerdink, Melvyn / Janssen, Thomas W.J. et al. | BASE | 2019

    Freier Zugriff


    Assessing walking adaptability in stroke patients

    Geerse, Daphne J. / Roerdink, Melvyn / Marinus, Johan et al. | BASE | 2021

    Freier Zugriff


    Polio survivors have poorer walking adaptability than healthy individuals

    Tuijtelaars, Jana / Roerdink, Melvyn / Raijmakers, Bart et al. | BASE | 2021

    Freier Zugriff